57
Following careful testing
and when the mains fre-
quency passes into the per-
missible range, the FRONI-
US IG will resume feeding
power into the mains.
104 Mains frequency in all
phases outside the per-
missible range
Check mains frequency
If this service code keeps
recurring, contact your
system engineer
Following careful testing
and when the mains fre-
quency passes into the per-
missible range, the FRONI-
US IG will resume feeding
power into the mains.
114 Mains frequency in
phase 1 outside the
permissible range
Check mains frequency
If this service code keeps
recurring, contact your
system engineer
Following careful testing
and when the mains fre-
quency passes into the per-
missible range, the FRONI-
US IG will resume feeding
power into the mains.
124 Mains frequency in
phase 2 outside the
permissible range
Check mains frequency
If this service code keeps
recurring, contact your
system engineer
Service codes in service class 1 generally only arise momentarily, and are caused by the
public mains network.
The initial response of the FRONIUS IG in this case is to disconnect itself from the
mains. The mains is subsequently checked for the stipulated monitoring period. If no
further problem has been detected by the end of this period, then the FRONIUS IG will
resume feeding power into the mains.
A list of service codes, associated designations, descriptions and corrective actions can
be found in the table below.
Class 1
Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.
101 Mains voltage in all
phases outside the per-
missible range
Code Designation Manifestation
Check mains voltage
If this service code keeps
recurring, contact your
system engineer
Remedy
Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.
111 Mains voltage in phase
1 outside the permis-
sible range
Check mains voltage
If this service code keeps
recurring, contact your
system engineer
Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.
121 Mains voltage in phase
2 outside the permis-
sible range
Check mains voltage
If this service code keeps
recurring, contact your
system engineer
Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.
131 Mains voltage in phase
3 outside the permis-
sible range
Check mains voltage
If this service code keeps
recurring, contact your
system engineer